How do you balance radiators after a new boiler?
If some rooms are toasty while others never quite warm up, the radiators probably need balancing. It is a simple idea that takes patience to get right, especially after a new boiler.
- Gas Safe registered (548390)
- Which? Trusted Trader
- Local to Renhold
- Written estimates before work starts
What balancing is
Hot water tends to reach the radiators nearest the boiler first, leaving those furthest away cooler. Balancing adjusts each radiator so the flow is shared fairly across the whole system. It matters most after a new boiler is fitted or the system is cleaned, because the way water flows changes.
How it is done
Each radiator usually has a control valve, often thermostatic and a lockshield valve under a plastic cap that is used for balancing.
- Bleed the radiators to remove trapped air.
- Open all the lockshield valves fully as a starting point.
- Heat the system and note which radiators warm up first.
- Partly close the lockshields on the fastest radiators.
- Measure the temperature going in and coming out of each radiator and adjust until the difference is similar across them all.
Signs your system needs balancing
- Rooms near the boiler heat much faster than the rest
- Far radiators, such as upstairs bedrooms, never fully warm
- The heating runs for a long time to warm the coldest room
- Some radiators are very hot while others are lukewarm
Balancing is different from bleeding. Bleeding removes air, while balancing adjusts the flow.
The benefits
- Even warmth throughout the house
- The boiler reaches its target and switches off sooner
- Less strain on the system
Balancing is easy to rush or skip, which is why some homes never feel right after a boiler change. Make sure it is included in your installation.
Our guide on matching radiators to your boiler explains the other half of the picture.
Common questions
Can I balance radiators myself?
It is possible with patience and a thermometer but it is methodical work and an engineer will usually get a better result.
Why are my radiators uneven after a new boiler?
The system often needs rebalancing after a new boiler or a power flush because the flow through the pipes has changed.